Redbusbar Pty Ltd :: DeadEasy
|
DeadEasy - Electrical Isolation, "Test for Dead" Voltage Indicator
DeadEasy is a 3 phase, “Test for Dead” test device. DeadEasy tests a circuit to establish whether the AC phase conductors are energised or deenergised (alive or dead). DeadEasy aims to provide non-electrical people with a simple and safe method of verifying MCC (Motor Control Centre) based, electrical isolations before conducting mechanical maintenance. See SwitChek for field isolation verification. In addition, confirmation of the deenergised state of the circuit inside a cabinet reduces the need to open the cabinet to conduct testing and hence expose personnel to a potential Arc Flash / Fault. Confirmation of the deenergised state of the circuit inside the cabinet may reduce the level of Arc Flash PPE required to open the cabinet door.
It is simple and fast to use. No licenses are necessary. Anyone can operate DeadEasy.
DeadEasy tests the circuit under test by sensing the existence or absense of an electric field surrounding an electrical conductor. In essence, DeadEasy is a permanently installed, non-contact voltage indicator. While this testing aproach is used extensively in medium and high voltage applications, DeadEasy's focus is low voltage (< 1,000VAC) systems. DeadEasy is implemented in a fixed mode, that is one DeadEasy is dedicated to one circuit. It is ideally suited to installation within a motor control centre on controlled circuits. Specifically, on the short length, circuit conductors between the isolating device (switch or circuit breaker) and the controlling device (contactor or variable speed drive).
The DeadEasy non-contact voltage detector is operated as follows:
-
With the Isolator on / closed / 1 the red LED only should be illuminated - Confirms that all 3 phases are
energised
-
With the Isolator off / opened / 0 the green LED only should be illuminated - Confirms that all 3 phases are
deenergised
-
With the Isolator off / opened / 0 and self test activated the red LED only should be illuminated - Confirms that 3 phase voltage sensing is operational and therefore validates the deenergised result achieved in step 2 above.
|
DeadEasy Operation Videos - Requires Sound
Turn your sound up and click on the link below to view a short video of DeadEasy in action ...
This first video indicates the DeadEasy result achieved when a
healthy isolation switch / circuit breaker / disconnect is tested...
This second video indicates the DeadEasy result achieved when a
faulty isolation switch / circuit breaker / disconnect is tested.
In order to watch the YouTube videos, you need the following system requirements:
-
Macromedia Flash Player 7.0+ plug-in
-
Windows 2000 or higher with latest updates installed
-
Mac OS X 10.3 or higher
-
Firefox 1.1+, Internet Explorer 5.0+ or Safari 1.0+
-
Broadband connection with 500+ kbps
If you cannot view the above videos you can download them using the links below (requires Windows Media player 9+):
DeadEasy Benefits
Users have commented that the DeadEasy non-contact voltage tester:
- Allows non-electricians to perform a "Test for Dead" style test on an electrical circuit.
- Is simple to use.
- Provides a positive result in dirty and dark environments. Green LED On = Isolated. Whereas “Pilot Lamp“ solution Off = Isolated or just lamp failure? = Inconclusive!
- Delivers test result confidence through an operator initiated Self Testing function.
- Does not compromise the integrity of the power system as DeadEasy does not electrically connect to the power circuit.
-
Is inexpensive.
-
Is simple to install. 25mm wide DIN rail mount electronics, HMI incorporating LED lamps and self test request all in one only 22.5mm panel lamp cut-out.
-
Has wide application. DeadEasy is suitable for new and retrofit installations and dusty, low and high ambient light environments.
-
Is flexible. DeadEasy allows subsequent verifications without reversal of the isolation ie accommodates late working parties.
-
Reduces exposure to arc flash / faults. The energised state of conductors is known before panel doors are opened to conduct tests.
-
Is reliable when compared to hand held, non-contact voltage testers. It does not depend on the user's low impedance to earth.
What is Isolation Confirmation?
Electrical Isolation Procedures / Lockout Tagout (LOTO) Procedures often require that electrical switches be tested so as to confirm that the switch is "electrically off" once the equipment has been isolated. Confirmation or verification is often performed on the following isolating equipment:
- Isolation Switches
- Disconnects
- Circuit Breakers (CBs)
Typical Isolation Procedure testing methods include:
- Testing Dead or Test for Dead
- Attempt Start
- Observation of Visual Break Isolators (VBIs)
- Pilot lamp indication of energised phases
In many cases these isolation verification methods are complex, potentially misleading and expensive to perform.
DeadEasy exposes unsafe electrical isolations by detecting a failed isolation switch.
More DeadEasy Information?
Visit the DeadEasy Support page for detailed datasheets.
Visit the DeadEasy FAQs page for typical DeadEasy questions and answers.
Altenatively, you can ask your own question by contacting us using one of the methods described on the Contact Us page.
More "Confirming Electrical Isolations" Information?
The "Confirming Electrical Isolations" in the Technical Paper section presents a full analysis of:
- Why you need to confirm electrical isolations
- What options are available to confirm electrical isolations
- What you need to consider when deciding on a method for confirm electrical isolations
- Industry Best Practice methods for confirming electrical isolations
| DeadEasy |
|
See details
|
DeadEasy30
Electrical Isolation Confirmation / Isolation Verification, Test for Dead Test Device - Base Unit
Note: Requires One DeadEasy (DE30), One DeadEasy Human Machine Interface (DE30HMI), One DeadEasy Human Machine Interface cable (DE30HMIC), Two DeadEasy Instrum...
Price (ex Tax) : AUD265.00
|
|
See details
|
DeadEasy30 Human Machine Interface
Electrical Isolation Confirmation / Isolation Verification, Test for Dead Test Device - Human Machine Interface
Note: Requires One DeadEasy (DE30), One DeadEasy Human Machine Interface (DE30HMI), One DeadEasy Human Machine Interface cable (DE30HMIC), Two D...
Price (ex Tax) : AUD125.00
|
|
See details
|
DeadEasy30 Human Machine Interface Cable
Electrical Isolation Confirmation / Isolation Verification, Test for Dead Test Device - Human Machine Interface Cable
Note: Requires One DeadEasy (DE30), One DeadEasy Human Machine Interface (DE30HMI), One DeadEasy Human Machine Interface cable (DE30HMIC),...
Price (ex Tax) : AUD10.00
|
|
See details
|
DeadEasy30 Interface Cable
Electrical Isolation Confirmation / Isolation Verification, Test for Dead Test Device - Interface Cable
Note: Requires One DeadEasy (DE30), One DeadEasy Human Machine Interface (DE30HMI), One DeadEasy Human Machine Interface cable (DE30HMIC), Two DeadEasy ...
Price (ex Tax) : AUD55.00
|
|
See details
|
DeadEasy30 Kit
Electrical Isolation Confirmation / Isolation Verification, Test for Dead Test Device - Kit for 1 Isolation Switch
Including One DeadEasy (DE30), One DeadEasy Human Machine Interface (DE30HMI), One DeadEasy Human Machine Interface cable (DE30HMIC), Two Dea...
Normal price:
AUD510.00
Price (ex Tax) : AUD495.00
save 3%
|
|
|
|
|